MORPHOLOGICAL CHANGES IN THE FATTY TISSUE AFTER A SINGLE EXPOSURE TO THE ULTRASOUND



Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription or Fee Access

Abstract

The morphological changes in the fatty tissue of the posterior surface of knee joint were studied in rats (n=96) using the method of light microscopy 1, 2, 3, 4 and 5 days after a single ultrasonic exposure of various duration (5, 10, 20 min)) in a diagnostic mode. This exposure resulted in hyperemia, lymphostasis and increase of vascular permeability. The degree of changes was found to increase in proportion to the duration of exposure. All the changes detected were reversible, and the majority of them disappeared within 1-2 days. During the practical application, it is necessary to take into account the possibility the induction of cell and tissue damage during the ultrasonographic examinations. Development and application of the measures directed to decrease the edema and to stabilize the vascular wall both during the ultrasonography and immediately after it are expedient. Ultrasonography should be performed only when there are significant medical indications, and to receive the required diagnostic information, the lowest power of the device should be used.

Full Text

Restricted Access

About the authors

I. V. Maiborodin

RAMS Siberian Branch Institute of Chemical Biology and Fundamental Medicine

Email: imai@mail.ru

R. Kh. Suleimanov

Kyrgyz-Russian Slavic University

S. A. Kim

Kyrgyz State Medical Institute for Retraining and Professional Development

I. I. Maiborodin

RAMS Siberian Branch Institute of Chemical Biology and Fundamental Medicine

References

  1. Кузин М. И. и Костюченок Б. М. Раны и раневая инфекция: Руководство для врачей. М., Медицина, 1990.
  2. Миллер Э., Хилл К., Бэмбер Дж. и др. Применение ультразвука в медицине. Физические основы. М., Мир, 1989.
  3. Ang E. S. Jr., Gluncic V., Duque A. et al. Prenatal exposure to ultrasound waves impacts neuronal migration in mice. Proc. Natl. Acad. Sci. USA, 2006, v. 103, № 34, p. 12903-12910.
  4. Casley-Smith J. R. The lymphatic system in inflammation. In: The inflammatory process, 1973, v. 2, 1973, p. 161-204.
  5. Forsberg F., Shi W. T., Merritt C. R. et al. On the usefulness of the mechanical index displayed on clinical ultrasound scanners for predicting contrast microbubble destruction. J. Ultrasound Med., 2005, v. 24, № 4, p. 443-450.
  6. Fowlkes J. B. Bioeffects committee of the american institute of ultrasound in medicine. American Institute of ultrasound in medicine consensus report on potential bioeffects of diagnostic ultrasound: executive summary. J. Ultrasound Med., 2008, v. 27, № 4, p. 503-515.
  7. Fowlkes J. B. and Holland C. K. Mechanical bioeffects from diagnostic ultrasound: AIUM consensus statements. American Institute of Ultrasound in Medicine. J. Ultrasound Med., 2000, v. 19, № 2, p. 69-72.
  8. Head J. R. and Seeling L. L. Jr. Lymphatic vessels in the uterine endometrium of virgin rats. J. Reprod. Immunol., 1984, v. 6, № 3, p. 157-166.
  9. Herman B. A. and Harris G. R. Theoretical study of steady-state temperature rise within the eye due to ultrasound insonation. IEEE Trans. Ultrason. Ferroelectr. Freq. Control, 1999, v. 46, № 6, p. 1566-1574.
  10. Horder M. M., Barnett S. B., Vella G. J. et al. In vivo heating of the guinea-pig fetal brain by pulsed ultrasound and estimates of thermal index. Ultrasound Med. Biol., 1998, v. 24, № 9, p. 1467-1474.
  11. Jago J. R., Henderson J., Whittingham T.A. and Mitchell G. A comparison of AIUM/NEMA thermal indices with calculated temperature rises for a simple third-trimester pregnancy tissue model. American Institute of Ultrasound in Medicine/National Electrical Manufacturers Association. Ultrasound Med. Biol., 1999, v. 25, № 4, p. 623-628.
  12. Kim Y. T., Kim H. C., Inada-Kim M. et al. Evaluation of tissue mimicking quality of tofu for biomedical ultrasound. Ultrasound Med. Biol., 2009, v. 35, № 3, p. 472-481.
  13. Merritt C. R. Ultrasound safety: what are the issues? Radiology, 1998, v. 173, № 2, p. 304-306.
  14. Miller D. L., Smith N. B., Bailey M. R. et al. Overview of therapeutic ultrasound applications and safety considerations. J. Ultrasound Med., 2012, v. 31, № 4, p. 623-634.
  15. O’Brien W. D. Jr., Deng C. X., Harris G. R. et al. The risk of exposure to diagnostic ultrasound in postnatal subjects: thermal effects. J. Ultrasound Med., 2008, v. 27, № 4, p. 517-535.
  16. O’Brien W. D. Jr. and Zachary J. F. Mouse lung damage from exposure to 30 kHz ultrasound. Ultrasound Med. Biol., 1994, v. 20, № 3, p. 287-297.
  17. Steinert R. F. and Schafer M. E. Ultrasonic-generated fluid velocity with Sovereign WhiteStar micropulse and continuous phacoemulsification. J. Cataract. Refract. Surg., 2006, v. 32, № 2, p. 284-287.
  18. Tsuruta J. K., Dayton P.A., Gallippi C. M. et al. Therapeutic ultrasound as a potential male contraceptive: power, frequency and temperature required to deplete rat testes of meiotic cells and epididymides of sperm determined using a commercially available system. Reprod. Biol. Endocrinol., 2012, v. 10, p. 7.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2014 Eco-Vector



СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: № 0110212 от 08.02.1993.

This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies