MORPHOLOGICAL CHARACTERISTICS OF REPARATIVE OSTEOGENESIS UNDER THE CONDITIONS OF TRANSOSSEOUS OSTEOSYNTHESIS AND INTRAMEDULLARY INTRODUCTION OF HYDROXYAPATITECOATED WIRES



Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription or Fee Access

Abstract

In the experiments performed on 16 dogs, an open comminuted tibial fracture was modeled, then wires with hydroxyapatite coating were inserted intramedullary, and osteosynthesis was performed using the Ilizarov fixator. Bone regenerates were studied 14-360 days after the surgery using the methods of light microscopy, scanning electron microscopy, and X-ray electron probe microanalysis. It was found that a zone of active reparative osteo- and angiogenesis was formed around the wires, as well as a bone sheath with the properties of osteogenesis conductor and inductor. Fracture consolidation occured early according to the primary type without cartilaginous and connective tissue formation in bone adhesion.

Full Text

Restricted Access

About the authors

Yu. M. Iryanov

G. A. Ilizarov Russian Scientific Center for Restorative Traumatology and Orthopedics

Email: irianov@mail.ru

A. V. Popkov

G. A. Ilizarov Russian Scientific Center for Restorative Traumatology and Orthopedics

N. I. Antonov

G. A. Ilizarov Russian Scientific Center for Restorative Traumatology and Orthopedics

References

  1. Агаджанян В. В., Твердохлебов С. Н., Больбасов Е. Н. и др. Остеоиндуктивные покрытия на основе фосфатов кальция и перспективы их применения при лечении политравм. Политравма, 2011, № 3, с. 5-13.
  2. Ирьянов Ю. М. и Дюрягина О. В. Влияние локального очага грануляционной ткани, сформированного в костномозговой полости, на репаративное костеобразование. Бюл. экспер. биол., 2014, т. 157, № 1, с. 121-125.
  3. Ирьянов Ю. М. и Ирьянова Т. Ю. Морфологическая характеристика грануляционной ткани, формирующейся в костном мозге при чрескостном остеосинтезе. Морфол. ведомости, 2010, № 3, с. 48-51.
  4. Крочек И. В., Привалов В. А., Крочек Г. В. и др. Оценка результатов лазерной остеоперфорации при лечении хронического остеомиелита. Лазерная мед., 2005, т. 9, № 3, с. 32-34.
  5. Ларионов А. А., Речкин М. Ю. и Асонова С. Н. Влияние остеотрепанации длинной трубчатой кости на остеорепарацию и регионарное кровообращение (экспериментальное исследование). Гений ортопедии, 1999, № 2, с. 80-85.
  6. Михайленков Р. В. Стимуляция гемопоэза при острой лучевой травме у животных. Успехи соврем. естествознания, 2007, № 5, с. 51-54.
  7. Попков Д. А. Применение интрамедуллярного армирования при удлинении конечности. Вестн. травматол. ортопед. им. Н. Н. Приорова, 2005, № 2, с. 65-69.
  8. Шевцов В. И., Ирьянов Ю. М., Петровская Н. В. и Ирьянова Т. Ю. Влияние кальций-фосфатного покрытия спиц на процессы минерализации и активность остеогенеза при чрескостном дистракционном остеосинтезе. Морфол. ведомости, 2008, № 3-4, с. 231-234.
  9. Coles C. P. and Gross M. Closed tibial shaft fractures: management and treatment complications. A review of the prospective literature. Can. J. Surg., 2000, v. 43, р. 256-262.
  10. Griffith L. E., Cook D. J. and Frulke J. P. Intramedullary Reaming of Long Bones. In: Practice of Intramedullary Locked Nails. New Development Techniques and Applications. Berlin - Heidelberg New York, Springer Verlag, 2006, p. 43-57.
  11. John V. Z., Alagappan M., Devadoss S. and Devadoss A. A completely shattered tibia. J. Bone Joint Surg. Br., 2005, v. 87, № 11, р. 1556-1559.
  12. Joseph В. and Rebello G. The choice of intramedullary devices for the femur and the tibia in osteogenesis imperfecta. J. Pediatr. Orthop., 2005, v. 14, № 5, р. 311-319.
  13. Lin C. M. and Yen S. K. Biomimetic growth of apatite on electrolytic TiO2 coatings in simulated body fluid. Mater. Sci. Eng. C Mater. Biol. Appl., 2006, v. 26, p. 54-64.
  14. Liu X., Chu P. K. and Ding C. Surface modification of titanim, titanim alloys and related materials for biomedical applicatios. Mater. Sci. Eng. C Mater. Biol. Appl., v. 47, p. 49-121.
  15. Schemitsch E. H., Kowalski M. J. and Swiontkowski M. F. Cortical bone blood flow in reamed and unreamed locked intramedullary nailing: a fractured tibia model in sheep. J. Orthop. Trauma, 1994, v. 8, р. 373-382.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2014 Eco-Vector



СМИ зарегистрировано Федеральной службой по надзору в сфере связи, информационных технологий и массовых коммуникаций (Роскомнадзор).
Регистрационный номер и дата принятия решения о регистрации СМИ: № 0110212 от 08.02.1993.

This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies